YHS-630
PRODUCT DESCRIPTION

    By putting its probe in direct contact with the workpiece, this detector can identify the leak location.

    With the sniffer probe in direct contact with a workpiece, the sensor detects a leak. The leak location is identified. Since installation is easy, the cost of installation is low.

    • The touch panel easy to understand at a glance and easy to operate
    • Sniffer probe to be in direct touch with a workpiece for identifying the leak location
features
  • Detection method : Sniffer method
  • Detectable leak rate : 1x10-6Pa~1×10--2Pa・m3/s
  • Feature : Inline support possible
specifications
Leak detector
YHS-600
Judgment leak rate
1×10-8~1×10-2Pa・m3/sec
Minimum detection leak rate
1×10-8Pa・m3/sec
Startup time
3 minutes
Number of analysis tube filaments
Double Filaments (2)
Analysis tube seal
Flat Gasket
Calibration
External
Temperature
10~40℃
Humidity
90% or less
Power supply
AC 100V±10% Single phase 50 / 60Hz 10A
Dimensions
W546mm x D378mm x H470mm
Weight
46kg